Travels of a CO2 datalogger

Travels of a CO2 datalogger

Feature articles |
By Rich Pell



Surprised by how high levels were on some occasions, GSS will be doing further investigations in other locations to see how CO2 levels vary in the real world.

The GSS CozIR-A CO2 sensor.

The datalogger used measures CO2 concentration, air pressure and temperature along with relative humidity every few minutes. It is a custom solution designed and built by GSS and uses one of its low power, ambient air, CozIR-A 5000 sensors.

This low power consumption enabled the datalogger to record over a 2-week period without needing a change of battery. The other sensors integrated in the module are an NXP MPL3115A2 pressure sensor and a Sensirion SHT21 temperature and humidity sensor.

The recorded data shows how the CO2 level in blue and the air pressure level in green fluctuated throughout the journey. It clearly shows increased levels of CO2 when there are a number of people in a confined space with limited ventilation to remove CO2 build up.

The World Health Organisation guideline is that CO2 levels should be below 1000 ppm, and ASHRAE (the American Society of Heating, Refrigeration and Air Conditioning Engineers) says that CO2 at high concentrations of 5000 ppm can pose a health risk.

CO2 and pressure readings during a 14-day trip to Asia.

The drop in air pressure on the graph shows the part of the journey that was in a plane. The train journeys show particularly high levels of CO2, where CO2 levels built up to over 2000 ppm.

Similar results are shown from the meeting room. However, perhaps surprisingly the highest CO2 peaks were during the taxi journeys with two passengers and a driver. This consistently produced levels in excess of the 5000 ppm health risk indicator mark and, at one point of the journey, even peaked at 10,000 ppm. This really shows the high levels of CO2 that people can be exposed to while driving through a busy city. 


How CO2 levels impact on the human body.

“Generally, people are still not aware of the problems of high CO2 concentrations,” explains Dr David Moodie, Technical Manager at GSS. “That drowsy sensation you often experience in a stuffy meeting room is caused by elevated levels of CO2.”

“The higher the level and the longer the exposure, the more apparent the effect is on the body. Travelling can often be tiring, leaving you feeling worn out. This real-world data shows how often you can be exposed to high levels of CO2 without realising it – even in taxis and trains – and this could be a significant factor in how you feel. So, my advice is to open windows whenever possible to let the CO2 out. Naturally that does not apply on planes!”

GSS technology
Most CO2 sensors work by measuring how much light is absorbed by CO2 molecules in the 4.2 to 4.4 microns range as it passes through the sample gas, which is called Non-Dispersive Infra-Red (NDIR) absorption. The amount of absorption indicates how much CO2 is present. GSS developed proprietary LEDs that are specifically tuned to emit at these wavelengths.

The LEDs use very little power and turn on almost instantly, enabling sensor readings to be made in a few seconds. As a result, GSS has pioneered the development of CO2 sensors that can be powered by batteries for long periods of up to ten years. Competing sensors use IR sources that require significantly more power per measurement and also take much longer to reach a stable condition for a measurement, resulting in the need for mains power.

About the author:
Lily Liu is GSS Business Development Manager at Gas Sensing Solutions (GSS) – www.gassensing.co.uk